Ovaj članak još nije pregledan na Vašem jeziku, pa se prikazuje engleski izvornik.
Elektroprijenos BiH Wins 46 Million Euro EBRD Support for Grid Voltage Control
EBRD approves up to 46 million euros for Elektroprijenos BiH to install variable shunt reactors, improving voltage stability as renewables expand.
The transmission system operator of Bosnia and Herzegovina, Elektroprijenos BiH, has secured approval for financing reaching up to 46 million euros from the European Bank for Reconstruction and Development. The capital will support the procurement and installation of variable shunt reactors across strategic high-voltage substations in the national transmission network.
As renewable energy penetration accelerates across the regional grid, variable generation from solar and wind assets introduces severe voltage regulation challenges. Lightly loaded high-voltage lines during periods of high renewable generation or low electricity demand produce significant excess reactive power, causing high busbar voltage levels across key corridors. Installing variable shunt reactors enables dynamic reactive power compensation, allowing network operators to adjust inductive absorption continuously rather than in fixed, discrete steps. This continuous regulation mitigates overvoltage spikes, smooths transient fluctuations, and protects critical substation assets from dielectric stress.
Without dynamic reactive power compensation, high-voltage power transformers face excessive operational stress. On-load tap changers are forced to operate frequently to maintain busbar voltages within regulatory limits, accelerating mechanical wear on contacts and increasing maintenance requirements for tap changer mechanisms and insulating fluids. Furthermore, variable shunt reactors help reduce switching transients across transmission nodes, enhancing overall network reliability.
What this means for asset owners in the Balkans and the Black Sea region: Grid operators and industrial power asset owners in Bosnia and Herzegovina facing increased renewable feed-in must review voltage control strategies at key high-voltage substations. The deployment of inductive reactive compensation helps stabilise line voltages, reducing thermal and dielectric stress on aging transformer insulation. Engineering teams should plan for potential temporary substation outages during installation, update insulation coordination studies, and ensure switchgear is rated for frequent inductive switching to prevent premature equipment degradation.
Analiza povezanog izvješća uz pomoć umjetne inteligencije.