First 7 turbines connected at Entek storage wind project in Ankara

Entek has grid-connected the first 7 turbines at its Ankara wind site, though operational status for the integrated energy storage system remains unconfirmed.

Obrázok: Yeşil Haber

The grid synchronisation of the initial 7 wind turbines at Entek’s Ankara development marks a notable step in phased renewable integration within the region. While generation from these turbines is now feeding into the grid, formal confirmation regarding the operational commissioning of the co-located battery storage system has not been issued. Staggered commissioning sequences of this nature are increasingly common across hybrid assets, where primary generation units achieve operational status ahead of energy storage subsystems.

For high-voltage engineering teams, bringing a partial turbine array online presents distinct electrical challenges at the main collector substation. Operating a sub-set of turbines, such as this group of 7, generates low-load conditions across large step-up transformers and internal medium-voltage collector networks. Under light power throughput, cable capacitance can lead to localized voltage rise, requiring precise reactive power management and dynamic tap-changer control on the main step-up transformers. Protection relays must also be adjusted for interim short-circuit levels, which differ significantly from full-build operational parameters.

Furthermore, delaying battery system energisation means the collector substation cannot rely on dynamic battery response to absorb switching transients or assist with local voltage control during initial turbine testing. Transformer protection schemes must remain vigilant regarding energisation inrush currents and harmonic distortion introduced by wind turbine converters operating under partial capacity.

What this means for asset owners in Türkiye: Engineers managing substation step-up transformers in Türkiye must review protection settings and voltage regulation logic during partial generation rollouts. Operating only 7 turbines alters reactive power dynamics on collector circuits, raising the risk of high-voltage stress on transformer bushings and cable insulation before energy storage assets come online. Asset managers should schedule active dissolved gas analysis and monitor tap-changer operations closely while partial generation feeds into the regional grid.