ZE Energy acquires 59 MW long-duration battery storage project in Italy

ZE Energy acquires a shovel-ready 59 MW, 472 MWh battery storage project in Italy featuring an 8 hour discharge duration and a 132 kV grid connection.

Immagine: pv magazine France

ZE Energy has expanded its Italian portfolio by acquiring a fully permitted, ready-to-build battery energy storage system project. The asset delivers an output capacity of 59 MW with up to 8 hours of storage duration, providing a total storage energy volume of 472 MWh. The plant will connect directly to the transmission network at 132 kV, representing a major addition to the region's utility-scale flexible asset pipeline.

Technical implications for substation assets

Long-duration storage facilities operating across continuous 8 hour discharge cycles introduce distinct duty profiles compared to short-duration ancillary service units. For transformer and switchgear engineers, severe thermal cycling becomes a dominant ageing factor. While rapid-response frequency regulation assets experience transient power spikes, a 472 MWh battery discharging at 59 MW subjects the main step-up transformer to sustained full-load operation over multi-hour blocks.

Connecting at 132 kV requires specialized substation equipment engineered for bi-directional active and reactive power flow. Power conversion systems generate harmonic emissions that alter voltage waveforms, placing dielectric and thermal stresses on transformer windings. Furthermore, high daily cycle counts accelerate mechanical wear on load tap changers and high-voltage circuit breakers.

To protect grid-tie infrastructure, engineering teams must evaluate cooling system redundancies, forced oil circulation, and online dissolved gas analysis monitoring. Operating a 59 MW facility with an 8 hour duty cycle necessitates proactive insulation diagnostics to detect incipient thermal faults before critical failures occur.

What this means for asset owners in Europe: Grid operators and storage developers across Italy must specify transformers and switchgear capable of handling heavy continuous thermal cycles associated with 8 hour storage duration assets connected at 132 kV. Operating 472 MWh facilities with 59 MW step-up stages demands strict dissolved gas analysis, tap changer maintenance, and harmonic filtering to prevent accelerated insulation degradation and maintain long-term substation reliability.